GCSE · Physics · AQA · Spec 8463

The National Grid

Sending 500 million watts at 230 V would need about 2 million amps, enough to melt the lines. So the National Grid plays a trick with the voltage.

Watch the heating take off

0250500750100001000200030004000Current in the line (A)Power dissipated by heating (kW)(500, 750)

Current in the line (A): 500. Power dissipated by heating (kW): 750

Slide the point. Pick a current, then double it and compare the two heating values.

Follow the electricity

Step through the journey from generator to user. Some stages hide an extra detail.

  1. Power station or wind turbineThe electricity is generated: often at about 25 kV in a power station and about 1000 V in a wind turbine.
  2. Step-down transformerAt the other end of the lines it decreases the voltage to the right size for the user.
  3. Homes and factoriesHomes use 230 V. Factories usually use a higher voltage than homes.
UK note

This is AQA GCSE Physics (8463) section 4.2.4.3, The National Grid, for both tiers.

Physics · Power and current

How many amps does 400 kV need?

A power station sends 500 million watts into the transmission lines at 400 000 V. Power = current × potential difference, P = I V. How many amps flow in the lines?

Your estimate

1500 A

0 A3000 A

The reasoning chain

?

Reason it through

Why does the National Grid use a very high voltage for the transmission lines?

Link 1 of 4

First link · your turn

The power to be sent is fixed. If the voltage is very high, what does P = I V say about the current?

2
Locked — reveal the link above first
3
Locked — reveal the link above first
4
Locked — reveal the link above first

Physics · Power dissipated by heating

Heating in 100 km of line

A 100 km transmission line has a resistance of 3 Ω. A current of 1000 A passes through it. Work out the power dissipated by heating, using P = I² R.

  1. Step 1: Current squared
  2. Step 2: Power dissipated
  3. Final question: On your own
What you are given
QuantityValue
Current1000 A
Resistance of the line3 Ω
  1. Step 1 of 2: Current squared

    Square the current first. That is the I² in P = I² R.

    Give your answer to 3 significant figures. Its unit is A².

    A²
  2. Step 2 of 2: Power dissipatedOpens when the step before it is right.

How a transformer works

Inside a transformer
~

Showing 1 layer: Transformer

Explore

Tap each part, in order: primary, core, secondary

Transformers need an alternating p.d. and are almost 100% efficient, so the power output is equal to the power input.

Simplified sketch, not to scale. The number of turns in each coil is not shown. Tap a part.

WHAT YOU'VE LEARNED

A quick recap of today's lesson.

Why the cables carry up to 400 000 volts, not 230

What you need to know

  • The National Grid is a network of high voltage transmission lines carrying electricity from power stations and wind turbines to consumers.
  • Power stations often generate electricity at about 25 kV, and wind turbines at about 1000 V.
  • The transmission lines carry up to 400 kV, with currents of over 1000 A. Homes use 230 V.
  • Step-up transformers increase the voltage to around 400 kV for the transmission lines.
  • Step-down transformers at the other end decrease it to the right size for the user, such as 230 V for homes.
  • Power = current × potential difference, P = I V. For a given power, a bigger voltage means a smaller current.
  • Have a goPriya says: 'More volts, so more current, obviously.' A line sends 600 W at 3 V, then the same 600 W at 6 V. Is Priya right?

    No. The current goes from 200 A to 100 A.

    P = I V, so with the power fixed, doubling V halves I. Priya treats the voltage as a push that adds current, but here the power is the thing held fixed.

  • The lines have a small resistance, about 3 Ω per 100 km, so a current heats them at a rate P = I² R.
  • Have a goThe current in a line is halved. By what factor does the heating of the line change?

    It falls to a quarter.

    Heating goes with I², and half squared is a quarter. Halving the heating would be the answer if it only depended on I, but it depends on I × I.

  • A very high current would heat the lines so quickly they would melt, so a very high voltage keeps the current, and wasted energy, low.
  • Have a goTrue or false: the grid uses 400 kV because the high voltage itself adds extra energy to the electricity. Say why.

    False. It is used to keep the current low for the power that has to be sent.

    Voltage on its own does not add power: P = I V. What matters is that a low current means little heating and no melting.

  • Even so, up to 10% of the power across the whole grid is dissipated by heating.
  • A transformer needs AC and is almost 100% efficient, so its power output is equal to its power input.

The big picture

The National Grid is a network of high voltage transmission lines that carries electricity from power stations and wind turbines to consumers. Step-up transformers raise the voltage to around 400 kV so that, for the same power, the current is low. The heating of the lines is P = I² R, so a low current means much less energy dissipated and the lines do not melt. Step-down transformers then lower the voltage to the right size for users, such as 230 V for homes.

Key points

1The National Grid carries electricity from power stations and wind turbines to consumers along high voltage transmission lines.
2Step-up transformers raise the voltage to around 400 kV; step-down transformers lower it to the right size for users, such as 230 V for homes.
3For a given power, P = I V means a very high voltage gives a low current.
4The heating of the lines is P = I² R, so a low current means much less energy dissipated, and the lines do not melt.
5Up to 10% of the power across the whole grid is still dissipated by heating.
6Transformers need AC and are almost 100% efficient, so the power output is equal to the power input.

Worked example

Problem

A power station sends 100 million watts (100 000 000 W) into transmission lines at 400 000 V. The lines have a resistance of 3 Ω. Work out the current in the lines, then the power dissipated by heating in them.

⚠ Watch out

Thinking the very high voltage is there to add extra power or energy. It does not: for the power that has to be sent, a higher voltage just means a smaller current, and a smaller current means less heating of the lines (P = I² R).

🧠

Memory hook

Volts up, amps down, and the heating falls with the square of the amps.

✓

Check yourself

Sam says: 'Stepping up to 400 kV adds extra energy to the electricity.' What would you say to Sam, and what does the step-down transformer do at the end?

Flashcards

(14)
What is the National Grid?
A high voltage transmission system of cables (the transmission lines, often seen between pylons) that gets electricity from power stations and wind turbines to the consumers who need it.
At roughly what voltages do power stations and wind turbines generate electricity?
Power stations often at about 25 kV, and wind turbines at about 1000 V.
What voltage and current do the transmission lines carry, and what voltage do homes use?
Lines: up to 400 kV (400 000 V), with currents of over 1000 A. Homes: 230 V.
What does a step-up transformer do in the National Grid?
It increases the voltage from the power station (or wind turbine) to around 400 kV for the transmission lines.
What does a step-down transformer do, and for whom?
At the other end of the lines it decreases the voltage to the right size for the user, such as 230 V for homes. Factories usually use a higher voltage than homes.
500 million W is sent at 400 kV. How many amps? And at 230 V?
1250 A at 400 kV. At 230 V it would be about 2 million A (an approximate figure).
Which equation gives the power dissipated by heating in a line, and how big is a line's resistance?
P = I² R. A line has a small resistance, about 3 Ω per 100 km.
What happens to the heating power in a line if the current is doubled?
It becomes four times as big, because the power depends on the current squared.
What would a very high current do to the transmission lines?
Heat them so quickly that they would melt.
How much of the power across the whole National Grid is dissipated by heating?
Up to 10%.
Name the parts of a transformer.
A primary coil and a secondary coil, wound on a soft iron core.
How does a transformer pass on a potential difference, and why does it need AC?
The alternating p.d. across the primary coil magnetises the core with a changing magnetic field, which induces a p.d. across the secondary coil. A steady supply would not make the field change.
A transformer is almost 100% efficient. What does that say about its power?
The power output is equal to the power input.
True or false: the grid uses 400 kV because the high voltage adds extra power or energy.
False. A voltage does not add power. For the power that has to be sent, a higher voltage means a lower current, and so less heating of the lines.

Tap any card to flip it, or use Study as deck to go through them one at a time. In the full lesson these run as a spaced-repetition deck — you rate each card Hard, Good or Easy and the tricky ones keep coming back until they stick.

Learning with Lightbulb is opening soon

You can use this lesson now. Join the waitlist and we'll let you know when the full Lightbulb experience is ready.

Keep me posted

More AQA GCSE Physics topics

See the full AQA Physics curriculum →

How this lesson was checked. This AQA GCSE Physics (specification 8463)lesson was published through Lightbulb Learning's human-designed editorial process — the educational standards, accuracy rules and publication checks it must pass were authored and approved by Philip Halpin. It passed subject-specific assessment, automated educational checks and technical publication verification before going live (publication checks completed 12 November 2026). Published pages are monitored, human spot-checking is ongoing across the lesson library, and anything found wrong is corrected or withdrawn. How our lessons are made and checked. Spotted a mistake? Email hello@lightbulblearning.co and we'll review it.